# # This file is part of the PyMeasure package. # # Copyright (c) 2013-2024 PyMeasure Developers # # Permission is hereby granted, free of charge, to any person obtaining a copy # of this software and associated documentation files (the "Software"), to deal # in the Software without restriction, including without limitation the rights # to use, copy, modify, merge, publish, distribute, sublicense, and/or sell # copies of the Software, and to permit persons to whom the Software is # furnished to do so, subject to the following conditions: # # The above copyright notice and this permission notice shall be included in # all copies or substantial portions of the Software. # # THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR # IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, # FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE # AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER # LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, # OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN # THE SOFTWARE. # import logging from pymeasure.instruments import Instrument, SCPIUnknownMixin from pymeasure.instruments.validators import truncated_range from pymeasure.adapters import VISAAdapter log = logging.getLogger(__name__) log.addHandler(logging.NullHandler()) class KeysightN5767A(SCPIUnknownMixin, Instrument): """ Represents the Keysight N5767A Power supply interface for interacting with the instrument. """ ############### # Current (A) # ############### current_range = Instrument.control( ":CURR?", ":CURR %g", """Control the DC current range in Amps, which can take values from 0 to 25 A. Auto-range is disabled when this property is set. (float)""", validator=truncated_range, values=[0, 25], ) current = Instrument.measurement(":MEAS:CURR?", """ Get current in Amps. """ ) ############### # Voltage (V) # ############### voltage_range = Instrument.control( ":VOLT?", ":VOLT %g V", """ Control the DC voltage range in Volts, which can take values from 0 to 60 V. Auto-range is disabled when this property is set. """, validator=truncated_range, values=[0, 60] ) voltage = Instrument.measurement("MEAS:VOLT?", """ Get a DC voltage measurement in Volts. """ ) ################# # _status (0/1) # ################# _status = Instrument.measurement(":OUTP?", """ Get power supply current output status. """, ) def enable(self): """ Enables the flow of current. """ self.write(":OUTP 1") def disable(self): """ Disables the flow of current. """ self.write(":OUTP 0") def is_enabled(self): """ Returns True if the current supply is enabled. """ return bool(self._status) def __init__(self, adapter, name="Keysight N5767A power supply", **kwargs): super().__init__( adapter, name, **kwargs ) # Set up data transfer format if isinstance(self.adapter, VISAAdapter): self.adapter.config( is_binary=False, datatype='float32', converter='f', separator=',' )