http://www.openzwave.com/device-database/019B:0202:0003
images/thermofloor/heatit056.png
https://products.z-wavealliance.org/products/3065/
Adding the device:
To add the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start adding mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Adding Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been added in the network. Confirmation will show Inc/EcL in the display. If adding fails, Err (error) will appear.
Z-TRM2fx
Heatit Z-TRM2fx is equipped with a single pole switch and it fits most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.). The thermostat can withstand a load of max 13A /2900W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors.
The thermostat has the capacity of up to 8 associations (relays, wall plugs etc.).
The thermostat is designed for electrical heating.
FEATURES
Floor sensor
External room sensor
Temperature limiter
Weekly program/setback via gateway or pilot wire
Multilevel sensor command class
Firmware updates (OTA)
Power metering
LED-diode
Can be used in connection with different NTC-sensors
Lock mode/child lock
Calibration
8 associations
Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class
https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3065/Manual_Heatit_Z-TRM2fx_ENG_3.1.pdf
Removing the device:
To remove the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start remove device in your home automation software. Start removing mode by pressing Center (confirm) button for approximately 2 seconds. The icon will appear in the display. Removing Mode is indicated in the display by some “circling” LED segments in the display until the timeout occurs after 20 seconds or the module has been removed in the network. Confirmation will show Inc/EcL in the display. If removing fails, Err (error) will appear.
CEPT (Europe)
By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset.
NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable.
Heatit Z-TRM2fx
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3065/xml
0
true
0
true
Set operation mode
Set sensor mode
Floor sensor type (10K NTC Default)
3-30 (0.3C - 3.0C) Default is 5 (0.5C)
50-400 (5.0C - 40.0C) Default is 50 (5.0C)
50-400 (5.0C - 40.0C) Default is 400 (40.0C)
50-400 (5.0C - 40.0C) Default is 50 (5.0C)
50-400 (5.0C - 40.0C) Default is 400 (40.0C)
50 - 400 (5.0C - 40.0C) Default is 210 (21.0C)
50-400 (5.0C - 40.0C) Default is 180 (18.0C)
50-400 (5.0C - 40.0C) Default is 210 (21.0C)
-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.
-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.
Show setpoint or calculated temperature on display(
0-100 (0 - 100%)
0-100 (0 - 100%)
0-100 (0 - 100%)
0-100 (0 - 100%)
0 (Report disabled)
30-32767 (30-32767 seconds)
0-100 (0.1C - 10.0C) Default is 10 (1.0C)
0 (Report disabled)
30-32767 (30-32767 seconds)
0-127 A delta value of 0 - 12.7 kWh will result in a metering report. Default is 10 (1.0 kWh)
true
true