http://www.openzwave.com/device-database/019b:2200:0003
images/thermofloor/heatit_zdim.png
https://products.z-wavealliance.org/products/3261
Zdim
https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3261/Manual_Heatit_Z-DIM_FW%201.0_Ver2019-A_ENG.pdf
Z-Wave rotary dimmer for different light sources. The LED dimmer dims at low load without the light flickering. Dimmer LED from 1-200VA, 230V halogen and incandescent bulbs, dimmable LED drivers and electronic transformers. Not affected by additional starting currents. Need L + N conductor connected.
The dimmer has end-turn function. This allows you to turn on the light and dimming with one dimmer, and then turn off the light with another dimmer. Convenient for example in stairs and corridors.
The dimmer fits into standard Elko, Schneider Exxact and Gira System 55 frame systems.
FUNCTIONS
- Z-wave rotary dimmer
- Scene controller
- Dims:
- LED
- 230V halogen
- Incandescent lightbulbs
- Dimable LED-drivers
- Electronic transformators
- Starts at 1VA and dims up to 200VA LED
- Trailing edge
- Multiway switching option
- Electronic thermal cutoff with automatic reset
- Firmware updates (OTA)
- Power metering
- Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class
CONNECTION
1. Disconnect the power.
2. Connect the live to the dimmer terminal marked "L".
3. Connect the neutral to the dimmer terminal marked "N".
4. Connect the neutral to the load terminal marked "N".
5. Connect the load terminal marked "L" to the dimmer terminal marked (see wiring
diagram).
6. Install the dimmer (A) in the wall box. Make sure that no wires are pinched.
7. Attach the cover (B) with the supplied nut (C).
8. Attach the button (D) with a simple push.
To use the multiway function (stairway function) a 230VAC rated momentary switch
can be connected as follows:
9. Connect the live to the toggle switch terminal marked "L".
10. Connect the toggle switch terminal marked to the dimmer terminal marked "S"
(see wiring diagram).
TECHNICAL DATA
Protocol Z-Wave, 868,4MHz
Chip Z-Wave 500 chip
SDK 6.71.03
Rated voltage 230V AC 50Hz
Power 1VA - 200VA
Input current 0,9A
Controls Push and rotary dimmer
Operating temperature -20°C - 40 °C
Connection Max. 2,5mm2
Flush mounting depth 15mm
IP Code IP 20
Size (LxWxH) 84 x 84 x 43mm
APPROVALS
Z-Wave Plus
CE
EN 55015/A2: 2009, EN 61547:2009
EN 61000-3-2/A2:2009
EN 61000-3-3:2008
EN 60669-2-1/A12:2010
EN 60669-1:A2:2008
EMC 2014/30/EU, RoHS 2011/65/EU
LVD 2014/35/EU
INCLUSION/EXCLUSION
Press the main button on dimmer 6 times in a rapid sequence. Heatit Z-DIM is now included in your Z-Wave network.
CEPT (Europe)
Heatit Zdim
FACTORY RESET - RES
By pressing and holding the main button for 20 seconds, the dimmer will perform
a complete factory reset. The connected light source will blink once and go in the
"OFF" state if successfully reset. NB! Please use this procedure only when the primary
controller is missing or otherwise inoperable
INCLUSION/EXCLUSION
Press the main button on dimmer 6 times in a rapid sequence. Heatit Z-DIM is now included in your Z-Wave network.
Initial release
Fixed COMMAND_CLASS_SWITCH_MULTILEVEL get commands
The parameter defines the value of connected load. Refer to Paragraph 8 "Power Metering".
0 = Default
1 - 200 = 1-200 Watts connected load
POWER METERING
The Heatit Z-Dim has functionality to calculate power consumption. To enable this
function, Parameter 1 "Connected load" should have a value greater than 0. This is an
estimated value, therefore power consumption accuracy depends on load estimation.
1. Estimate the load value (Watt) connected to the Heatit Z-Dim.
2. Use this value in Parameter 1.
Heatit Z-Dim can report accumulated (kWh) and instant (Watt), or only instant (Watt)
power consumption. The report time interval can be altered by Parameter 9.
The parameter defines the lowest dimming level of the dimmer. The value must be lower than parameter 3 "Maximum Dim Level"
1% - 98% Default is 20 (20%)
The parameter defines the highest dimming level of the dimmer.
The value must be higher than parameter 2 "Minimum Dim Level"
2% - 99% Default is 85 (85%)
The parameter defines how many steps it should take to dim from minimum
to maximum dim level (One round = 20 steps).
5 - 255 = 5-255 steps. Default is 15 (3/4 round)
The parameter defines the double press functionality.
Enables scene controller
The parameter defines the dimming level when restored from the OFF state
by push button.
0 = Restores last dim level (Default)
1 - 99 = 1% - 99%
The parameter defines how long it takes to dim to the desired level.
Note! Only Multilevel Switch Command Class is affected by this parameter.
0 = Disabled
1 - 127 = Duration in seconds (1 - 127 seconds. Default is 1)
128 - 255 = Duration in minutes (1 - 127 minutes)
The parameter defines the report interval for Power Metering.
30 - 32767 = Duration in seconds (30 - 32 767. Default is 60)
The parameter defines the initial dimming level after power loss.
1 - 99 = 1% - 99% Default is 50 (50%)
false
true