Qubino Flush Dimmer 0-10V
The Qubino Flush Dimmer 0-10V is a universal dimmer with a standard 0-10V output and a multi-function input, which may be a push button or switch, a potentiometer or a 0-10V signal. It also measures power consumption and supports the connection of a digital temperature sensor.
• Connect module to power supply
• bring module within maximum 1 meter (3 feet) of the main controller,
• enable add/remove mode on main controller,
• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.
By this function all parameters of the module are set to default values and own ID is deleted.
If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
NOTE 1: If the module is included with parameter 1 value 3, 4 or 5 and module reset is done, wait at least 30s before next inclusion.
NOTE 2: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
CEPT (Europe) / Australia / New Zealand / U.S. / Canada / Mexico
ZMNHVD3
• Connect module to power supply (with
temperature sensor connected - if purchased),
• enable add/remove mode on main controller
• auto-inclusion (works for about 5 seconds after connected to power supply) or
• press service button S for more than 2 second or
• press push button I1 three times within 3s (3 times change switch state within 3 seconds).
NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2196/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2216/xml
Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/2241/xml
NOTE: After parameter change to value 3, 4 or 5 first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!
Responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
0 => Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto OFF enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0
0 - Auto OFF disabled. 1 - 32535 => 1 second (0,01s) - 32535 seconds (325,35s). Auto ON enabled with define time, step is 1s or 10ms according to parameter 15. Default value 0
This parameter is influencing on the software only when the value of parameter number 1 is set to value 3, 4 or 5.
In manual mode regulation (how the input influence on output) is disabled.
NOTE: When ZERO PID inside deadband is forced to zero.
Last value means that PID remains on same level as was before entering into deadband.
0 to 100 => 0 to 100%, step is 1%.
Default value 1.
NOTE: This parameter defines the zone where PID is not active. If the temperature difference between actual and setpoint is bigger than PID deadband, then the PID will start to regulate the system, otherwise the PID is zero or fixed.
0 to 127 => 0 to 127s, step is 1s.
Default value 1.
Parameter defines the time between samples. On each sample the controller capture difference between SP-act.
0 to 1000, step is 1.
Default value 100.
0 to 1000, step is 1.
Default value 1.
0 to 1000, step is 1.
Default value 1.
1 - 98 = 1% - 98%, step is 1%. Minimum dimming values is set by entered value.
Default value 1 (Minimum dimming value is 1%).
2 - 99 = 2% - 99%, step is 1%. Maximum dimming values is set by entered value.
Default value 99 (Maximum dimming value is 99%).
Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through.
1- 255 = 10mseconds - 2550mseconds (2,55s), step is 10mseconds.
Default value 100 (Dimming time between min. and max. dimming values is 1s).
Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1.
1- 255 = 1 second - 255 seconds.
Default value 3 (Dimming time between min. and max. dimming values is 3s).
This parameter is used with association group 4.
A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0.
A receiving device MUST ignore the start level if the Ignore Start Level bit is 1.
Default value 0.
This parameter is used with association group 3.
The Duration field MUST specify the time that the transition should take from the current value to the new target value.
A supporting device SHOULD respect the specified Duration value.
Default value 0.
From 1 to 100 - value from 0.1 C to 10.0 C is added to actual measured temperature.
From 1001 to 1100 - value from -0.1 C to -10.0 C is subtracted to actual measured temperature.
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
Available settings: 0 - Reporting disabled.
1 - 127 = 0,1C - 12,7C, step is 0,1C.
If analogue sensor is connected, module reports measured value on change defined by this parameter.
0 - Reporting disabled.
1 to 10000, step is 0.1.
Default value 5 => 0.5C.
Parameter is associated with Association group No. 2.
Below this value, the Association No. 2 will report Basic Set 0xFF and above this value will report Basic Set 0xFF.
Basic Set is reported only, when the input value changes for more than 10% (1V).
Default setting: 5 (0.5V)
1 to 100 => (0,1 to 10V)
Value that must correspond to minimum sensor range value.
Valid only if parameter 1 is set to values 3, 4 or 5).
default value 0 = 0.0C / 0Lux / 0.0%rh
0 to 10000 => value from 0 to 1000 (resolution 0,1)
10001 to 20000 => value from -0,1 to -1000 (resolution 0,1)
NOTE: Minimum value must not be higher than maximum value!
Value that must correspond to maximum sensor range value.
Valid only if parameter 1 is set to values 3, 4 or 5).
default value 1000 = 100.0C / 100Lux / 100.0%rh
0 to 10000 => value from 0 to 1000 (resolution 0,1)
10001 to 20000 => value from -0,1 to -1000 (resolution 0,1)
NOTE: Maximum value must not be lower than minimum value!