http://www.openzwave.com/device-database/0159:0051:0005 images/qubino/ZMNHIDx.png 1. Connect the device to the power supply 2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held Z-Wave remote to perform exclusion 3. Enable add/remove mode on your Z-Wave gateway (hub) 4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds OR If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds 5. The device will be removed from your network but any custom configuration parameters will not be erased The Qubino Flush On/Off Thermostat 2 is ideal for remotely controlling electric or water-based underfloor heating systems, electric water heaters, hot water pumps, electric radiators, and similar devices. CEPT (Europe) 1. Enable add/remove mode on your Z-Wave gateway (hub) 2. Connect the device to the power supply (with the temperature sensor already connected*) 3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times press of the switch. OR If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2 and 6 seconds 4. A new multi-channel device will appear on your dashboard *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor. ZMNHID1 Qubino Flush On Off thermostat Z-Wave+ H1S2P1 1. Connect the device to the power supply 2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds (5 times change switch state) OR If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds Add missing parameter 59 2 0 Flush on off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. When I1 is pressed set point will be set according to the value of this parameter. Default value 1. 32767 - input I1 does not influence on the set point From 0 to 990 - set point from 0.0 C to 99.0 C From 1001 to 1150 - set point from -0.1 C to -15.0 C When I3 is pressed set point will be set according to the value of this parameter. Default value 32767. 32767 - input I2 does not influence on the set point From 0 to 990 - set point from 0.0 C to 99.0 C From 1001 to 1150 - set point from -0.1 C to -15.0 C When I3 is pressed set point will be set according to the value of this parameter. Default value 32767. 32767 - input I3 does not influence on the set point From 0 to 990 - set point from 0.0 C to 99.0 C From 1001 to 1150 - set point from -0.1 C to -15.0 C Set value from 0 - 100 (0% - 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 0 Set value means time interval (0 - 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 0 This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating on. The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. Default value 132 (-0.5 C) This parameter defines temperature min difference between real measured temperature and set-point temperature to turn heating off. The parameter can be set from 0 to 1127 where 0 to 127 means from 0.0 C to 12.7 C and from 1001 to 1127 means from - 0.1 C to -12.7 C. Default value 5 (+0.5 C) Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. 0 - 127 = 0.0C - 12.7 C. 1001 - 1127 = -0.1C - 12.6 C. 255 - Antifreeze functionality disabled. Default value 50 (5.0 C). This parameter determines how the device will operate if it will operate in the heating mode or in the cooling mode. The range of the hysteresis will remain the same, only operation will change from heating to cooling and vice versa Default value 50 (Minimum Temperature alarm is 5.0C) 1 - 1000 = 0.1C - 100.0C, step is 0.1C. 1001 - 1150 = -0.1 C - 15 C Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Default value 700 (Minimum Temperature alarm is 70.0C) 1 - 1000 = 0.1C - 100.0C, step is 0.1C. Too high temperature limit is set by entered value. In case is set value out of this range, module is changing automatically set value to default value. Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). Available config. parameters (data type is 1 Byte DEC): default value 0 0 - When system is turned off the output is 0 V. 1 - When system is turned off the output is 230 V. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 11. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 11. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the condense sensor functionality is selected by the parameter no. 12. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the condense sensor functionality is selected by the parameter no. 12. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the flood sensor functionality is selected by the parameter no. 13. Default value 0 1 - 32000 seconds If the value of the parameter is different to 0, means that the influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the flood sensor functionality is selected by the parameter no. 13. Enabling I1 means that Endpoint (I1) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. NOTE 1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module! NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. Set value is added or subtracted to actual measured value by sensor. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. Default value 32536. 32536 offset is 0.0C. If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C If digital temperature sensor is not connected, module can grab measured temperature from external secondary module. Default value is 0. If digital temperature sensor is not connected, module can grab measured temperature from external battery powered room sensor defined by this paramater. 0 = external battery powered room sensor not in function. 1 to 254 = Node ID of external battery powered room sensor. Default value is 0