http://www.openzwave.com/device-database/0159:0051:0002 images/qubino/ZMNHBDx.png https://products.z-wavealliance.org/products/1528/ ZMNHB Please use this procedure only in the event that your network primary controller is missing or otherwise inoperable. If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state Module Exclusion/Reset (Removing from Z-Wave network) • Connect module to power supply • bring module within maximum 1 meter (3feet) of the main controller, • enable add/remove mode on main controller, • press service button S for more than 6 second or • press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. By this function all parameters of the module are set to default values and own ID is deleted. If service button S is pressed more than 2 and less than 6second module is excluded, but configuration parameters are not set to default values Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. CEPT (Europe) Module Inclusion (Adding to Z-Wave network) • Connect module to power supply (with temperature sensor connected - if purchased), • enable add/remove mode on main controller • auto-inclusion (works for about 5 seconds after connected to power supply) or • press service button S for more than 2 second or • press push button I1 three times within 3s (3 times change switch state within 3 seconds). NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply. NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module. Qubino Flush 2 relays https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/1528/Qubino_Flush 2 Relay PLUS extended manual_eng_2.2.pdf Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1528/xml Flush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. When Q1 relay is ON it goes automatically OFF after set time. The timer is reset to zero every time the module receives an ON command from any source. Value is in 1s or 10ms depending on parameter 15 When Q1 relay is OFF it goes automatically ON after set time. The timer is reset to zero every time the module receives an OFF command from any source. Value is in 1s or 10ms depending on parameter 15 When Q2 relay is ON it goes automatically OFF after set time. The timer is reset to zero every time the module receives an ON command from any source. Value is in 1s or 10ms depending on parameter 15 When Q2 relay is OFF it goes automatically ON after set time. The timer is reset to zero every time the module receives an OFF command from any source. Value is in 1s or 10ms depending on parameter 15 Select the time units for auto on/off configuration. Applies tot he whole device Set value from 0 - 100 (0%- 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 Set value from 0 - 100 (0%- 100%). 0 - Reporting Disabled. 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Default value 1 Set value means time interval (0 1 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) Set value means time interval (0 1 65535) in seconds, when power report is send. 0 - Reporting Disabled. 1 - 65535 = 1 second - 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Default value 300 (power report in Watts is send each 300s) Type of device that is connected to the output (NC or NO) Type of device that is connected to the output (NC or NO) Set value is added or subtracted to actual measured value by sensor. Available configuration parameters : default value 32536. 32536 offset is 0.0C. From 1 to 100 = value from 0.1C to 10.0C is added to actual measured temperature. From 1001 to 1100 = value from -0.1 C to -10.0 C is subtracted to actual measured temperature. If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters : 0 = reporting disabled. 1 to 127 = 0,1C to 12,7C, step is 0,1C. Default value is 5 = 0,5C true