MH-P220
Restoring Factory Settings:
The default configuration can be restored by:
* Sending commands through controller/gateway (the command classes which support this function is Configuration Command Class). The parameter are as follows:
Parameter Number 0xFF
Size 1 BYTE
Default value N/A
Configuration value 0x55
Set 0xFF as 0x55 will restore Factory Settings.
* Or press the inner button on the module 10 times in quick succession.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3011/MH-P220UserManual.pdf
U.S. / Canada / Mexico
Remove the device from Z-Wave network:
1. Set controller into REMOVE mode. Follow the instructions provided by the controller/gateway manufacturer.
2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession.
Note: If the REMOVE is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state.
Micro Dimmer MHP-220
This in-wall module is with compact design as well as stable performance, which can suit for any of the installation box and various operation situation. It supports basic command class, and also can act as repeater regardless of vendor to increase reliability of the network.
Add the device into Z-Wave network:
1. Set controller into ADD mode. Follow the instructions provided by the controller/gateway manufacturer.
2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession.
Note: If the ADD is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switch’s state.
Initial Metadata Import from Z-Wave Alliance Database - file based on 1.4 version by @tonbor PR #1853
Dimmer state saved or not when power down
External switch type
2-state Switches
ALL ON/ALL OFF
Minimum brightness level
Maximum brightness level
Single dimming step time(Manual)
Single dimming step size (Manual)
Single dimming step time (Auto)
Single dimming step size (Auto)
Timer function (Auto-off)
One click of S1
Double click of S1
Operation report from Switch1 to Association Group 2 and 3
Operation report from Switch1 to Association Group 2
Switch 2 function
Operation report from Switch2 to Association Group 4
Scene ID sent to AG1 when one click of S2
Scene ID sent to AG1 when double click of S2
Scene ID sent to AG1 when hold S2