MIMOlite
MIMOlite
Make virtually anything speak Z-wave™! The MiMOlite Module is an interface / bridge module, capable of converting a wire or wireless input to a wire or wireless output. It provides one relay to wirelessly control low voltage applications & one signal input to connect a digital, analog, or pulse signal into your Z-waveTM network.
Common Applications
Garage Doors & Motorized Gates
Wired Door Bells / Chimes
Control Solenoids
Connect to existing wired buttons
Security Panel Zone-in
Motorized Shades
Connect to various wired sensors including Temperature probes, Soil Moisture probes, Float switches, Level Sensors, Reed Switches, Door / Window sensors, etc.
Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1756/xml
Clear Pulse Meter Counts (actual value is dont care; count gets reset whenever
this command is received regardless of value). This parameter is for SIG1 only.
SIG1 triggered/untriggered sets or clears Relay1.
Refer to description in User Manual under section, Input to Relay Mapping. Note
that neither a Basic Report nor a Binary Switch Report is sent when relay is
automatically set or cleared by Trigger Mapping. Only applies to the Relay1 output.
SIG1 high lower threshold.
Must be less than Upper Threshold Low and greater than Lower Threshold Low.
SIG1 low lower threshold.
SIG1 high upper threshold.
SIG1 low upper threshold.
Must be greater than Lower Threshold High and less than Upper Threshold High.
Bits 7 - 2 are ignored and should be set to 0
Bit1 : Digital-Configuration flag
1=Set Trigger levels for this channel to digital thresholds (approx. 1V); Default
0=Set Trigger levels to analog thresholds (see parameters 4 through 7)
Bit0 : Trigger-Between-Thresholds flag (see below)
1 = Set to triggered when input falls between thresholds; Default
0 = Set to triggered when input falls outside of thresholds
Periodic send interval of Multilevel Sensor Reports (Association Group 2) and/or
Pulse Count Reports (Association Group 5) for SIG1. This parameter has a resolution
of 10 seconds; for example, 1 = 10 seconds, 2 = 20 seconds, 3 = 30 seconds (Default),
... 255 = 2550 seconds = 42.5 minutes. A value of 0 disables automatic reporting.
Momentary Relay1 output enable/disable.
1..255 = enable / value sets the approximate momentary on time in increments
of 100msec.