digraph G { graph [center=true, color=white, compound=true, fontcolor=black, fontname=Helvetica, fontsize=14, penwidth=0.1, ratio="0,01" ]; node [color="#bdd7e7", fillcolor="#eff3ff", fontcolor="#2171b5", fontname=Helvetica, fontsize=13, label="\N", shape=ellipse, style=filled ]; edge [color="#9ecae1", fontcolor="#3182bd", fontname=Helvetica, fontsize=10, style=solid ]; "Prepare DAQ/Pre Set Event" [label="Pre Set Event"]; "Prepare DAQ/Pre Set Event" -> "Check if there is at least\none active IC headstage"; "Check if there is at least\none active IC headstage" -> "Check if no TTL channels are active"; "Check if no TTL channels are active" -> "All required analysis parameters present?"; "All required analysis parameters present?" -> "Check if all active IC\n headstages have the same stimset"; "Check if all active IC\n headstages have the same stimset" -> "All checks passed"; "All checks passed" -> Abort [label=No]; "All checks passed" -> "Set DAScale to 100pA\nfor all active IC headstages" [label=Yes]; "Set DAScale to 100pA\nfor all active IC headstages" -> "Write initial stepsize of 100pA into\nlabnotebook for all active IC headstages"; "Write initial stepsize of 100pA into\nlabnotebook for all active IC headstages" -> "Set \"DAScale exceeded\" labnotebook entry\nto false for all active IC headstages"; "Set \"DAScale exceeded\" labnotebook entry\nto false for all active IC headstages" -> "Store active headstages in labnotebook"; "Start DAQ/RA (only call for last active headstage)" -> "Prepare DAQ/Pre Set Event"; "Start DAQ/RA (only call for last active headstage)" -> "Post Sweep Event"; "Start DAQ/RA (only call for last active headstage)" -> "Post DAQ Event"; "Start DAQ/RA (only call for last active headstage)" -> "Post Set Event"; n60 [label="Pre DAQ Event"]; "Start DAQ/RA (only call for last active headstage)" -> n60; "Post Sweep Event" -> "Iterate over all active headstages"; "Post Sweep Event" -> "Store pulse duration in labnotebook"; "Post DAQ Event" -> "Update Dashboard"; "Post Set Event" -> "Mark set as passed if 1 sweep passed,\nas failure otherwise"; "Post Set Event" -> "Set \"TP during ITI\" to enabled"; n60 -> "Enable \"Multidevice DAQ\""; "Iterate over all active headstages" -> "Active headstages left?"; "Mark set as passed if 1 sweep passed,\nas failure otherwise" -> "Analysis parameter \"PostDAQSetDAScale\" is true"; "Set \"TP during ITI\" to enabled" -> "Set \"TP inserting\" to enabled"; "Enable \"Multidevice DAQ\"" -> "Enable \"Repeated Acquisition\""; "Active headstages left?" -> "Have all headstages passed in one sweep\nof their stimset cycle?" [label=No]; "Active headstages left?" -> "Headstage passed?" [label=Yes]; "Analysis parameter \"PostDAQSetDAScale\" is true" -> "Set DAScale to the stored LBN value taking into account\nthe analysis parameter \"PostDAQDAScaleFactor\"\nand \"PostDAQDAScaleMinOffset\"\ .\nSet it to \"PostDAQDAScaleForFailedHS\" for failed headstages."; n61 [label="Is \"Unlocked indexing\" active"]; "Enable \"Repeated Acquisition\"" -> n61; "Have all headstages passed in one sweep\nof their stimset cycle?" -> "Mark sweep as failed" [label=No]; "Have all headstages passed in one sweep\nof their stimset cycle?" -> "Mark sweep as passed" [label=Yes]; "Headstage passed?" -> "Headstage exceeded DAScale\n according to labnotebook entry?" [label=No]; "Set DAScale to the stored LBN value taking into account\nthe analysis parameter \"PostDAQDAScaleFactor\"\nand \"PostDAQDAScaleMinOffset\"\ .\nSet it to \"PostDAQDAScaleForFailedHS\" for failed headstages." -> "Read active headstages from labnotebook\nand turn them all on again"; n61 -> Abort [label=Yes]; "Mark sweep as failed" -> "Have all active headstages an DAScale exceeded\n labnotebook entry?"; "Mark sweep as passed" -> "Skip to end of active set"; "Headstage exceeded DAScale\n according to labnotebook entry?" -> "Spike detected?\n(x range: pulse onset to end of sweep\ny condition: max above 0.01mV)\nStore result in labnotebook" [label=No]; "Have all active headstages an DAScale exceeded\n labnotebook entry?" -> "Skip to end of active set" [label=Yes]; "Spike detected?\n(x range: pulse onset to end of sweep\ny condition: max above 0.01mV)\nStore result in labnotebook" -> "Step size from labnotebook? (1)" [label=Yes]; "Spike detected?\n(x range: pulse onset to end of sweep\ny condition: max above 0.01mV)\nStore result in labnotebook" -> "Step size from labnotebook? (2)" [label=No]; "Step size from labnotebook? (1)" -> "Store DAScale in labnotebook" [label="+10pA"]; "Step size from labnotebook? (1)" -> "Offset DAScale by -50pA" [label="-50pA"]; "Step size from labnotebook? (1)" -> "Write step size of -50pA to labnotebook" [label="+100pA"]; "Step size from labnotebook? (2)" -> "Write step size of +10pA to labnotebook" [label="-50pA"]; "Step size from labnotebook? (2)" -> "Offset DAScale by +10pA" [label="+10pA"]; "Step size from labnotebook? (2)" -> "Offset DAScale by +100pA" [label="+100pA"]; "Store DAScale in labnotebook" -> "Mark headstage as passed"; "Offset DAScale by -50pA" -> "Mark headstage as failed"; "Write step size of -50pA to labnotebook" -> "Offset DAScale by -50pA"; "Write step size of +10pA to labnotebook" -> "Offset DAScale by +10pA"; "Offset DAScale by +10pA" -> "Mark headstage as failed"; "Offset DAScale by +100pA" -> "Mark headstage as failed"; "Mark headstage as passed" -> "Set DAScale to zero"; "Mark headstage as failed" -> "\"MaximumDAScale\" analysis parameter is not NaN?"; "Store active headstages in labnotebook" -> "Turn off active non-IC headstages"; "\"MaximumDAScale\" analysis parameter is not NaN?" -> "DAScale is larger than \"MaximumDAScale\"?" [label=Yes]; "Disable \"dDAQ\"/\"oodDAQ\"" -> "Set \"TP during ITI\" to disabled"; "Set \"TP during ITI\" to disabled" -> "Set \"ITI\" to 100ms"; "Set \"ITI\" to 100ms" -> "Set \"TP inserting\" to disabled"; "Turn off active non-IC headstages" -> "Set \"User onset delay\" to 0ms"; "Set \"User onset delay\" to 0ms" -> "Set \"Termination delay\" to 0 ms"; "Set \"Termination delay\" to 0 ms" -> "Disable \"dDAQ\"/\"oodDAQ\""; "DAScale is larger than \"MaximumDAScale\"?" -> "Mark headstage as \"DAScale exceeded\"\nin labnotebook" [label=Yes]; "Mark headstage as \"DAScale exceeded\"\nin labnotebook" -> "Set DAScale to zero"; }