0 --> =0 2D, =1 AXISYMMETRIC 0 --> =0 Euler, =1 Navier-Stokes 1.e2 --> Reynolds by meter (the mesh is given in meter) 0. --> inverse of Froude number (=0 no gravity) 0.8 --> inflow Mach number 1. --> ratio pout/pin 1 --> wall =1 newmann b.c.(adiabatic wall), =2 (isothermal wall) 300. --> inflow temperature (in Kelvin) for Sutherland laws 288. --> if isothermal walls , wall temperature (in Kelvin) 0.0 --> angle of attack 1 --> Euler fluxes =1 roe, =2 osher,=3 kinetic 3 --> nordre = 1st order scheme, =2 2ndorder, =3 limited 2nd order 1 --> =0 global time steping (unsteady), =1 local Euler, =2 local N.S. 1. --> cfl LastIteration --> number of time step 500 --> frequence for the solution to be saved 1.e10 --> maximum physical time for run (for unsteady problems) -4. --> order of magnitude for the residual to be reduced (for steady problems) INIT --> =0 start with uniform solution, =1 restart from INIT_NS cccc turbulence ccccccccccccccccccccccccccccccccccccccccccccccccccccccc 0 --> =0 no turbulence model, =1 k-epsilon model 0 --> =0 two-layer technique, =1 wall laws 1.e-2 --> delta in wall laws or limit of the one-eq. model. (in meter) 0 --> =0 start from uniform solution for k-epsilon, =1 from INIT_KE -1.e10 1.e10 -1.e10 1.e10 --> xtmin,xtmax,ytmin,ytmax (BOX for k-epsilon r.h.s)