:: Initial Developer's Public License. :: The contents of this file are subject to the Initial Developer's Public :: License Version 1.0 (the "License"). You may not use this file except :: in compliance with the License. You may obtain a copy of the License at :: http://www.ibphoenix.com?a=ibphoenix&page=ibp_idpl :: Software distributed under the License is distributed on an "AS IS" basis, :: WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License :: for the specific language governing rights and limitations under the :: License. :: :: The Original Code is copyright 2003-2004 Paul Reeves. :: :: The Initial Developer of the Original Code is Paul Reeves :: :: All Rights Reserved. :: ::============================================================================= @echo off set SCRIPT_FULL_NAME=%~d0%~p0%~n0%~x0 set SCRIPT_SHORT_NAME=%~n0%~x0 @goto :MAIN @goto :EOF ::============================================================================ :SET_PARAMS ::========= @echo off :: reset ERRLEV to clear error from last run in same cmd shell set ERRLEV= :: Assume we are preparing a production build set FBBUILD_BUILDTYPE=release :: Don't ship pdb files by default set FBBUILD_SHIP_PDB=no_pdb :: Reset "make" vars to zero set FBBUILD_ZIP_PACK=0 set FBBUILD_ISX_PACK=0 if not defined FB2_SNAPSHOT (set FB2_SNAPSHOT=0) :: See what we have on the command line @for %%v in ( %* ) do ( ( if /I "%%v"=="DEBUG" (set FBBUILD_BUILDTYPE=debug) ) ( if /I "%%v"=="PDB" (set FBBUILD_SHIP_PDB=ship_pdb) ) ( if /I "%%v"=="ZIP" (set FBBUILD_ZIP_PACK=1) ) ( if /I "%%v"=="ISX" (set FBBUILD_ISX_PACK=1) ) ( if /I "%%v"=="ALL" ( (set FBBUILD_ZIP_PACK=1) & (set FBBUILD_ISX_PACK=1) ) ) ) :: Are we doing a snapshot build? If so we always do less work. if "%FB2_SNAPSHOT%"=="1" ( ( set FBBUILD_ISX_PACK=0 ) ) ::End of SET_PARAMS ::----------------- @goto :EOF :CHECK_ENVIRONMENT ::================ :: Make sure we have everything we need. If something is missing then :: let's bail out now. @echo o Checking for sed... @(cmd /c "sed.exe --version 2>&1 > nul ") || ( call :ERROR Could not locate sed & goto :EOF ) @echo o Checking for unix2dos... @(cmd /c "unix2dos.exe --quiet --version 2>&1 > nul" ) || ( call :ERROR Could not locate unix2dos & goto :EOF ) @for /f "usebackq tokens=*" %%c in ( `where /f md5sum 2^>nul` ) do set MD5_COMMAND=%%c @if defined MD5_COMMAND ( echo o POSIX md5sum utility found at %MD5_COMMAND% ) @if %FBBUILD_ZIP_PACK% EQU 1 ( if not defined SEVENZIP ( if exist "%ProgramW6432%\7-Zip\7z.exe" set SEVENZIP=%ProgramW6432%\7-Zip ) if not defined SEVENZIP ( call :ERROR SEVENZIP environment variable is not defined. goto :EOF ) else ( echo o Compression utility found. ) ) @if %FBBUILD_ISX_PACK% NEQ 1 goto :SKIP_INNO @if defined INNO6_SETUP_PATH ( set ISCC_COMMAND=%INNO6_SETUP_PATH%\iscc.exe ) :: If the environment variable is not set let's search in PATH @if not defined ISCC_COMMAND ( for /f "usebackq tokens=*" %%c in ( `where /f iscc 2^>nul` ) do set ISCC_COMMAND=%%c ) @if not defined ISCC_COMMAND ( echo Required Inno Setup compiler not found exit /b 1 ) @echo o Inno Setup found as %ISCC_COMMAND%. :SKIP_INNO @if not defined WIX ( echo. echo The WIX environment var not defined. echo WiX is needed to build the MSI kits of the CRT runtimes. echo. ) else ( echo o WiX found at "%WIX%". ) @if not defined FB_EXTERNAL_DOCS ( echo. echo The FB_EXTERNAL_DOCS environment var is not defined echo It should point to the directory containing the relevant release notes echo in adobe pdf format. echo. ) else ( echo o Package will include documentation from "%FB_EXTERNAL_DOCS%". ) ::End of CHECK_ENVIRONMENT ::------------------------ @goto :EOF :SET_VERSION ::========== :: Cut off everything that is not #define to let Inno Setup use it @findstr /B /L "#define" "%FB_ROOT_PATH%\src\jrd\build_no.h" > "%FB_ROOT_PATH%\gen\jrd\build_no.h" :: Read version parameters from build_no.h @for /F "tokens=2*" %%a in ( %FB_ROOT_PATH%\gen\jrd\build_no.h ) do ( echo Setting %%a to %%~b SET %%a=%%~b ) :: Set our package number at 0 and increment every :: time we rebuild in a single session @if not defined FBBUILD_PACKAGE_NUMBER ( set FBBUILD_PACKAGE_NUMBER=0 ) else ( set /A FBBUILD_PACKAGE_NUMBER+=1 ) @echo Setting FBBUILD_PACKAGE_NUMBER to %FBBUILD_PACKAGE_NUMBER% :: If a suffix is defined (usually for an RC) ensure it is prefixed correctly. @if defined FBBUILD_FILENAME_SUFFIX ( if not "%FBBUILD_FILENAME_SUFFIX:~0,1%"=="-" ( set FBBUILD_FILENAME_SUFFIX=-%FBBUILD_FILENAME_SUFFIX% ) ) :: Set up our final destination @set FBBUILD_INSTALL_IMAGES=%FB_ROOT_PATH%\builds\install_images @if not exist "%FBBUILD_INSTALL_IMAGES%" ( mkdir "%FBBUILD_INSTALL_IMAGES%" ) :: Determine Product Status @if %FB_BUILD_TYPE%==V ( set FBBUILD_PROD_STATUS=PROD ) else ( set FBBUILD_PROD_STATUS=DEV ) @set FBBUILD_FILE_ID=%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER%-%FB_TARGET_PLATFORM% @setlocal @echo. @if not exist %FB_GEN_DIR%\readmes ( mkdir %FB_GEN_DIR%\readmes ) @set SED_COMMAND=sed -e s/\$MAJOR/%FB_MAJOR_VER%/g ^ -e s/\$MINOR/%FB_MINOR_VER%/g ^ -e s/\$RELEASE/%FB_REV_NO%/g @echo Processing version strings in Readme_%FBBUILD_PROD_STATUS%.txt @%SED_COMMAND% Readme_%FBBUILD_PROD_STATUS%.txt > %FB_GEN_DIR%\readmes\Readme.txt @for %%f in ( installation_readme.txt installation_scripted.txt ) do ( echo Processing version strings in %%f %SED_COMMAND% %%f > %FB_GEN_DIR%\readmes\%%f ) @for %%d in (ba cz de es fr hu it pl pt ru si ja ) do ( if not exist %FB_GEN_DIR%\readmes\%%d ( mkdir %FB_GEN_DIR%\readmes\%%d ) for %%f in ( %%d\*.txt ) do ( echo Processing version strings in %%f %SED_COMMAND% %%f > %FB_GEN_DIR%\readmes\%%f ) ) @endlocal :: Dump env vars to file for later testing. @set > %FB_ROOT_PATH%\builds\install\arch-specific\win32\test_installer\fb_build_vars_%PROCESSOR_ARCHITECTURE%.txt ::End of SET_VERSION ::---------------- @goto :EOF :COPY_XTRA :: system dll's we need :: MSVC should be installed with redistributable packages. ::===================== :: We are forced to set this because the runtime library now (MSVC15) :: has a different version to the compiler. And sometimes they use 141 :: and sometimes 140. @if %MSVC_VERSION% EQU 15 ( set MSVC_RUNTIME_MAJOR_VERSION=14 set MSVC_RUNTIME_MINOR_VERSION_0=0 set MSVC_RUNTIME_MINOR_VERSION_1=1 ) else ( set MSVC_RUNTIME_VERSION=%MSVC_VERSION%0 ) @echo Copying MSVC runtime libraries... @if not exist %FB_OUTPUT_DIR%\system32 ( mkdir %FB_OUTPUT_DIR%\system32 ) @for %%f in ( msvcp%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_0%.dll vcruntime%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_0%.dll ) do ( echo Copying "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%.CRT\%%f" copy "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%.CRT\%%f" %FB_OUTPUT_DIR%\ >nul if ERRORLEVEL 1 ( call :ERROR Copying "%VCToolsRedistDir%\%VSCMD_ARG_TGT_ARCH%\Microsoft.VC%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%.CRT\%%f" failed with error %ERRORLEVEL% & goto :EOF ) ) @if "%VSCMD_ARG_TGT_ARCH%"=="x86" ( echo Generating fbclient_bor.lib where /Q implib.exe if not ERRORLEVEL 1 ( implib %FB_OUTPUT_DIR%\lib\fbclient_bor.lib %FB_OUTPUT_DIR%\fbclient.dll > nul ) else ( call :WARNING implib not found ) ) @if "%FBBUILD_SHIP_PDB%"=="ship_pdb" ( echo Copying pdb files... copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\chacha\chacha.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\engine\engine*.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\fb_lock_print\fb_lock_print.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\fbserver\firebird.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\fbsvcmgr\fbsvcmgr.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\fbtrace\fbtrace.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\fbtracemgr\fbtracemgr.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\gbak\gbak.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\gfix\gfix.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\gstat\gstat.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\ib_util\ib_util.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\intl\fbintl.pdb %FB_OUTPUT_DIR%\intl\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\isql\isql.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\legacy_auth\legacy_auth.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\legacy_usermanager\legacy_usermanager.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\nbackup\nbackup.pdb %FB_OUTPUT_DIR%\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\srp\srp.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\udf_compat\udf_compat.pdb %FB_OUTPUT_DIR%\plugins\udr\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\udrcpp_example\udrcpp_example.pdb %FB_OUTPUT_DIR%\plugins\udr\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\udr_engine\udr_engine.pdb %FB_OUTPUT_DIR%\plugins\ > nul copy %FB_TEMP_DIR%\%FBBUILD_BUILDTYPE%\yvalve\fbclient.pdb %FB_OUTPUT_DIR%\ > nul ) @echo Started copying docs... @rmdir /S /Q %FB_OUTPUT_DIR%\doc 2>nul @mkdir %FB_OUTPUT_DIR%\doc @copy %FB_ROOT_PATH%\*.md %FB_OUTPUT_DIR%\doc\ > nul @copy %FB_ROOT_PATH%\doc\*.* %FB_OUTPUT_DIR%\doc\ > nul @if ERRORLEVEL 1 ( call :ERROR COPY of main documentation tree failed. goto :EOF ) @echo Copy various upgrade scripts and docs @for %%d in ( v3.0 v4.0 ) do ( mkdir %FB_OUTPUT_DIR%\misc\upgrade\%%d 2>nul copy %FB_ROOT_PATH%\src\misc\upgrade\%%d\*.* %FB_OUTPUT_DIR%\misc\upgrade\%%d > nul if ERRORLEVEL 1 ( call :ERROR copy %FB_ROOT_PATH%\src\misc\upgrade\%%d\*.* %FB_OUTPUT_DIR%\misc\upgrade\%%d failed. goto :EOF ) ) @echo Copy INTL script @copy %FB_ROOT_PATH%\src\misc\intl.sql %FB_OUTPUT_DIR%\misc\ > nul @if ERRORLEVEL 1 ( call :ERROR copy %FB_ROOT_PATH%\src\misc\intl.sql %FB_OUTPUT_DIR%\misc failed. goto :EOF ) @echo Copying other documentation... @copy %FB_GEN_DIR%\readmes\installation_readme.txt %FB_OUTPUT_DIR%\doc\installation_readme.txt > nul @mkdir %FB_OUTPUT_DIR%\doc\sql.extensions 2>nul @if ERRORLEVEL 2 ( ( call :ERROR MKDIR for doc\sql.extensions dir failed) & ( goto :EOF ) ) @copy %FB_ROOT_PATH%\doc\sql.extensions\*.* %FB_OUTPUT_DIR%\doc\sql.extensions\ > nul @if ERRORLEVEL 1 ( ( call :ERROR Copying doc\sql.extensions failed ) & ( goto :EOF ) ) :: External docs aren't necessary for a snapshot build, so we don't throw :: an error if FB_EXTERNAL_DOCS is not defined. On the other hand, :: if the docs are available then we must include them. @if defined FB_EXTERNAL_DOCS ( echo Copying essential pdf docs... for %%v in ( Firebird_v%FB_MAJOR_VER%.%FB_MINOR_VER%.%FB_REV_NO%.ReleaseNotes.pdf ) do ( echo ... %FB_EXTERNAL_DOCS%\%%v to %FB_OUTPUT_DIR%\doc\%%v copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul if ERRORLEVEL 1 ( call :ERROR Copying %FB_EXTERNAL_DOCS%\%%v to %FB_OUTPUT_DIR%\doc\%%v FAILED. & goto :EOF ) ) echo Copying optional pdf docs... for %%v in ( Firebird-%FB_MAJOR_VER%.%FB_MINOR_VER%-QuickStart.pdf ) do ( echo ... %%v copy /Y %FB_EXTERNAL_DOCS%\%%v %FB_OUTPUT_DIR%\doc\%%v > nul if ERRORLEVEL 1 ( call :WARNING Copying %FB_EXTERNAL_DOCS%\%%v to %FB_OUTPUT_DIR%\doc\%%v FAILED. ) ) echo Finished copying pdf docs... echo. ) @echo Cleaning irrelevant files... :: Clean out text notes that are either not relevant to Windows or :: are only of use to engine developers. @for %%v in ( README.makefiles README.user.embedded README.user.troubleshooting README.build.mingw.html README.build.msvc.html fb2-todo.txt cleaning-todo.txt install_win32.txt README.coding.style emacros-cross_ref.html firebird_conf.txt *.*~) do ( @del %FB_OUTPUT_DIR%\doc\%%v 2>nul ) @echo Copy license... :: Add license for %%v in (IPLicense.txt IDPLicense.txt ) do ( @copy %FB_ROOT_PATH%\builds\install\misc\%%v %FB_OUTPUT_DIR%\%%v > nul ) :: And readme @copy %FB_GEN_DIR%\readmes\Readme.txt %FB_OUTPUT_DIR%\ > nul :: Walk through all docs and transform any that are not .txt, .pdf or .html to .txt @echo Setting .txt filetype to ascii docs. @for /R %FB_OUTPUT_DIR%\doc %%v in ( * ) do ( if /I not "%%~xv" == ".md" ( if /I not "%%~xv" == ".txt" ( if /I not "%%~xv" == ".pdf" ( if /I not "%%~xv" == ".htm" ( if /I not "%%~xv" == ".html" ( ren %%v %%~nxv.txt ) ) ) ) ) ) @if %FB2_SNAPSHOT% EQU 1 ( copy %FB_ROOT_PATH%\builds\install\arch-specific\win32\readme_snapshot.txt %FB_OUTPUT_DIR%\readme_snapshot.txt > nul ) @echo Completed copying docs. :: Examples were already copied by make_examples ::End of COPY_XTRA ::---------------- @goto :EOF :BUILD_CRT_MSI :: Generate runtimes as an MSI file. :: This requires WiX 3.0 to be installed ::============ @if %MSVC_VERSION% EQU 15 ( if not exist %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%_%FB_TARGET_PLATFORM%.msi ( "%WIX%\bin\candle.exe" -v -sw1091 %FB_ROOT_PATH%\builds\win32\msvc%MSVC_VERSION%\VCCRT_%FB_TARGET_PLATFORM%.wxs -out %FB_GEN_DIR%\vccrt_%FB_TARGET_PLATFORM%.wixobj if ERRORLEVEL 1 ( ( call :ERROR Could not generate wixobj for MSVC Runtime MSI ) & ( goto :EOF ) ) else ( "%WIX%\bin\light.exe" -sw1076 %FB_GEN_DIR%\vccrt_%FB_TARGET_PLATFORM%.wixobj -out %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%_%FB_TARGET_PLATFORM%.msi if ERRORLEVEL 1 ( (call :ERROR Could not generate MSVCC Runtime MSI ) & (goto :EOF)) ) ) else ( echo Using an existing build of %FB_OUTPUT_DIR%\system32\vccrt%MSVC_RUNTIME_MAJOR_VERSION%%MSVC_RUNTIME_MINOR_VERSION_1%_%FB_TARGET_PLATFORM%.msi ) ) ::End of BUILD_CRT_MSI ::-------------------- @goto :EOF :INCLUDE_DIR ::========== :: Prepare other files needed for deployment to /include dir @setlocal :: grab some missing bits'n'pieces from different parts of the source tree ::========================================================================= @echo Copying ib_util etc @copy %FB_ROOT_PATH%\src\extlib\ib_util.h %FB_OUTPUT_DIR%\include > nul || (call :ERROR Copying ib_util.h failed. & goto :EOF ) @copy %FB_ROOT_PATH%\lang_helpers\ib_util.pas %FB_OUTPUT_DIR%\include > nul || (call :ERROR Copying ib_util.pas failed. & goto :EOF ) @echo Copying other include files required for development... @set OUTPATH=%FB_OUTPUT_DIR%\include @copy %FB_ROOT_PATH%\src\yvalve\perf.h %OUTPATH%\ > nul @copy %FB_ROOT_PATH%\src\include\gen\firebird.pas %OUTPATH%\firebird\ > nul || (@call :ERROR Failure executing copy %FB_ROOT_PATH%\src\include\gen\firebird.pas %OUTPATH%\firebird\ ) @if ERRORLEVEL 1 goto :END @endlocal ::End of INCLUDE_DIR ::------------------ @goto :EOF :DB_CONF :: Generate sample databases file ::=============================== @echo Creating sample databases.conf @copy %FB_ROOT_PATH%\builds\install\misc\databases.conf %FB_OUTPUT_DIR%\databases.conf > nul ::End of DB_CONF ::----------------- @goto :EOF :MISC ::============================================== :: Make sure that qli's help.fdb is available ::=============================================== @if not exist %FB_OUTPUT_DIR%\help\help.fdb ( (@echo Copying help.fdb for qli support) (@copy %FB_GEN_DIR%\dbs\help.fdb %FB_OUTPUT_DIR%\help\help.fdb > nul) (@if %ERRORLEVEL% GEQ 1 ( (call :ERROR Could not copy qli help database ) & (goto :EOF))) ) ::End of MISC ::----------------- @goto :EOF :FB_MSG ::================================================================= :: firebird.msg is generated as part of the build process :: in builds\win32 by build_msg.bat. Copying from there to output dir ::================================================================= @if not exist %FB_OUTPUT_DIR%\firebird.msg ( copy %FB_GEN_DIR%\firebird.msg %FB_OUTPUT_DIR%\firebird.msg > nul if ERRORLEVEL 1 ( call :ERROR Could not copy firebird.msg & goto :EOF ) ) ::End of FB_MSG ::------------- @goto :EOF :SET_CRLF :: Get a list of all files in the tree make sure :: that and they all have windows EOL ::=============================================== @for /R %FB_OUTPUT_DIR% %%W in ( *.txt *.conf *.sql *.c *.cpp *.hpp *.h *.bat *.pas *.e *.def *.rc *.md *.html ) do ( unix2dos --safe %%W > nul 2>&1 || exit /b 1 ) ::End of SET_CRLF ::------------- @goto :EOF :ZIP_PACK ::======= :: Forcefully disable delayed expansion because of exclamation marks in 7z switches @setlocal DisableDelayedExpansion @set SKIP_FILES=-x!installation_readme.txt @if "%FBBUILD_SHIP_PDB%" == "ship_pdb" ( set FBBUILD_ZIPFILE=%FBBUILD_INSTALL_IMAGES%\Firebird-%FBBUILD_FILE_ID%-pdb%FBBUILD_FILENAME_SUFFIX%.zip ) else ( set FBBUILD_ZIPFILE=%FBBUILD_INSTALL_IMAGES%\Firebird-%FBBUILD_FILE_ID%%FBBUILD_FILENAME_SUFFIX%.zip set SKIP_FILES=%SKIP_FILES% -x!*.pdb ) :: No need to ship this file with the msi runtime @set SKIP_FILES=%SKIP_FILES% -x!*.wixpdb @if "%FB2_EXAMPLES%" == "0" set SKIP_FILES=%SKIP_FILES% -xr-!examples @if exist %FBBUILD_ZIPFILE% del %FBBUILD_ZIPFILE% @%SEVENZIP%\7z.exe a -r -tzip -mx9 %SKIP_FILES% %FBBUILD_ZIPFILE% %FB_OUTPUT_DIR%\* @endlocal ::End of ZIP_PACK ::---------------- @goto :EOF :ISX_PACK ::======= :: Now let's go and build the installable .exe :: :: Note - define INNO6_SETUP_PATH with double quotes if it is installed into a path string using spaces. :: eg set INNO6_SETUP_PATH="C:\Program Files\Inno Setup 6" :: ::================================================= @echo. @call %ISCC_COMMAND% %FB_ROOT_PATH%\builds\install\arch-specific\win32\FirebirdInstall.iss @echo. ::End of ISX_PACK ::--------------- @goto :EOF :DO_MD5SUMS ::========= :: Generate the md5sum checksum file ::================================== @if not defined MD5_COMMAND ( call :WARNING md5sum utility not found. Cannot generate md5 sums. goto :EOF ) @echo Generating md5sums for Firebird-%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER% :: write sums into temporary file to avoid including it into the process @pushd %FBBUILD_INSTALL_IMAGES% @call %MD5_COMMAND% Firebird-%PRODUCT_VER_STRING%?%FBBUILD_PACKAGE_NUMBER%*.* > md5sum.tmp :: then rename it to the proper name @if not ERRORLEVEL 1 ( del Firebird-%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER%.md5sum >nul 2>nul ren md5sum.tmp Firebird-%PRODUCT_VER_STRING%-%FBBUILD_PACKAGE_NUMBER%.md5sum ) else ( echo Error calling %0 & popd & @goto :END ) @popd ::End of DO_MD5SUMS ::----------------- @goto :EOF :HELP ::=== @echo. @echo. @echo Parameters can be passed in any order. @echo Currently the recognised params are: @echo. @echo DEBUG Use binaries from 'debug' dir, not 'release' dir. @echo (Requires a debug build. NOTE: A debug build is @echo not required to create packages with debug info.) @echo. @echo PDB Include pdb files. @echo (These files roughly double the size of the package.) @echo. @echo ISX Create installable binary from InnoSetup Extensions compiler. @echo (You need to set the INNO6_SETUP_PATH environment variable.) @echo. @echo ZIP Create Zip package. @echo (SEVENZIP is currently used and the SEVENZIP env var must be set.) @echo. @echo ALL Build InnoSetup and Zip packages. @echo. @echo HELP This help screen. @echo. @echo In addition, the following environment variables are checked by ISS script: @echo. @echo FB2_ISS_DEBUG=1 - Prepare an InnoSetup script that is @echo easier to debug @echo. @echo FB2_EXAMPLES=0 - Don't include examples in the install kit. @echo. @echo. @echo Required Files @echo. @echo To successfully package Firebird you will need to make sure several @echo packages are installed and correctly configured on your system. @echo. @echo o InnoSetup is needed to create the binary installer. See the header @echo of the .iss file to see which minimum version is required. @echo. @echo o 7ZIP is required to create the zip package @echo. @echo o sed is required for packaging. Use the sed provided by @echo gnuwin32. The cygwin one is not guaranteed to work. @echo. @echo o WiX v3.0 is required to build installable msi packages of the @echo MS runtime libraries. @echo. ::End of HELP ::----------- @goto :EOF :ERROR ::==== :: errorlevel gets reset automatically so capture it before we lose it. @set ERRLEV=%ERRORLEVEL% @echo. @echo Error code %ERRLEV% in %SCRIPT_SHORT_NAME% @echo %* @echo. ::End of ERROR ::------------ @goto :END :WARNING ::====== @set ERRLEV=%ERRORLEVEL% @echo. @echo **** WARNING - Execution of a non-critical component failed with error level %ERRLEV%. **** @echo %* @echo. @if "%FBBUILD_PROD_STATUS%" == "PROD" ( echo. echo Production status is Final or Release Candidate echo Error %ERRLEV% must be fixed before continuing echo. ) else ( set ERRLEV= ver > nul ) ::End of WARNING ::-------------- @goto :EOF :MAIN ::==== ::Check if on-line help is required @for %%v in ( %1 %2 %3 %4 %5 %6 %7 %8 %9 ) do ( if /I "%%v"=="-h" ( goto :HELP & goto :EOF ) if /I "%%v"=="/h" ( goto :HELP & goto :EOF ) if /I "%%v"=="HELP" ( goto :HELP & goto :EOF ) ) pushd ..\..\..\win32 ::This must be called from the directory it resides in. @call setenvvar.bat @if ERRORLEVEL 1 ( popd & ( call :ERROR Failure after calling setenvvar.bat ) & goto :END ) popd @if not defined FB2_ISS_DEBUG (set FB2_ISS_DEBUG=0) @echo. @echo Reading command-line parameters... @(call :SET_PARAMS %* ) @if ERRORLEVEL 1 (call :ERROR Calling SET_PARAMS & goto :END) @echo. @echo Checking that all required components are available... @( call :CHECK_ENVIRONMENT ) || ( echo Error calling CHECK_ENVIRONMENT & goto :END ) @echo. @echo Setting version number... @( call :SET_VERSION ) || ( echo Error calling SET_VERSION & goto :END ) @echo. @echo Copying additional files needed for installation, documentation etc. @( call :COPY_XTRA ) || ( echo Error calling COPY_XTRA & goto :END ) @echo. :: WIX is not necessary for a snapshot build, so we don't throw :: an error if WIX is not defined. On the other hand, :: if it is there anyway, use it. @if defined WIX ( echo Building MSI runtimes ( call :BUILD_CRT_MSI ) || ( echo Error calling BUILD_CRT_MSI & goto :END ) echo. ) @echo Prepare include directory @( call :INCLUDE_DIR ) || ( echo Error calling INCLUDE_DIR & goto :END ) @echo. @echo Writing databases conf @( call :DB_CONF ) || ( echo Error calling DB_CONF & goto :END ) @echo. @echo Copying miscellany such as the QLI help database @( call :MISC ) || ( echo Error calling MISC & goto :END) @echo. @echo Copying firebird.msg @( call :FB_MSG ) || ( echo Error calling FB_MSG & goto :END ) @echo. @echo Fix up line endings... @( call :SET_CRLF ) || ( echo Error calling SET_CRLF & goto :EOF ) @echo. @if %FBBUILD_ZIP_PACK% EQU 1 ( echo Zipping files for zip pack ( call :ZIP_PACK ) || ( echo Error calling ZIP_PACK & goto :END ) echo. ) @if %FBBUILD_ISX_PACK% EQU 1 ( echo Now let's compile the InnoSetup scripts ( call :ISX_PACK ) || ( echo Error calling ISX_PACK & goto :END ) echo. ) @( call :DO_MD5SUMS ) || ( echo Error calling DO_MD5SUMS & goto :END) @echo. @echo Completed building installation kit(s) @echo. :: If we got this far then be sure to reset ERRLEV :: because run_all.bat will check for ERRLEV @set ERRLEV= ::End of MAIN ::----------- @goto :END :END exit /b %ERRLEV%