Description: Convert MIB file to UTF-8 Lintian complains about a file with national-encoding. Author: Valentin Vidic Last-Update: 2025-05-05 --- This patch header follows DEP-3: http://dep.debian.net/deps/dep3/ --- a/agents/apc_snmp/powernet369.mib +++ b/agents/apc_snmp/powernet369.mib @@ -6643,16 +6643,16 @@ ACCESS read-write STATUS mandatory DESCRIPTION - "A reboot command uses the Initiator’s Return battery Capacity (RBC) to control + "A reboot command uses the Initiator’s Return battery Capacity (RBC) to control when the SCG completes this operation. In a Normal Control Operation (NCC) the UPS will only complete the reboot if RBC is reached. Due to normal battery charge rate variations it may be desirable for the Followers to complete the - reboot if they are within some range of the Initiator’s RBC when the Initiator + reboot if they are within some range of the Initiator’s RBC when the Initiator is prepared (charged to RBC) to complete the reboot. The Return Battery Capacity Offset (RBCO) defines a percent battery capacity subtracted from an - RBC above which a Follower’s battery must be charged for it to complete a - reboot. For example, if the Initiator’s RBC is 50% and the Initiator’s RBCO is - 5% then a Follower’s battery capacity is within range if it is greater or equal + RBC above which a Follower’s battery must be charged for it to complete a + reboot. For example, if the Initiator’s RBC is 50% and the Initiator’s RBCO is + 5% then a Follower’s battery capacity is within range if it is greater or equal to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot command. The default RBCO is 10%. " ::= { upsSyncCtrlGroupConfig 4 } @@ -6756,7 +6756,7 @@ "An ASCII string containing the 64 flags representing the current state(s) of the UPS. If the Network Card is unable to determine the state of the UPS, this - variable is set to ‘UNKNOWN’. + variable is set to ‘UNKNOWN’. The flags are numbered 1 to 64, read from left to right. The flags are defined as follows: @@ -6853,9 +6853,9 @@ "An ASCII string containing the 32 flags representing the current active UPS faults. If the Network Card is unable to determine the values of the flags, this - variable is set to ‘UNKNOWN’. If this variable is not + variable is set to ‘UNKNOWN’. If this variable is not supported by the connected UPS, this variable is set to - ‘NOT SUPPORTED’. + ‘NOT SUPPORTED’. The flags are numbered from 1 to 32, and read from left to right. The flags are defined as follows: @@ -6910,8 +6910,8 @@ the current active UPS specific faults for the Symmetra 3-Phase UPS models. If the Network Card is unable to determine the values of the flags, this variable is set - to ‘UNKNOWN’. If the connected UPS does not use this - variable, it is set to ‘NOT SUPPORTED’. + to ‘UNKNOWN’. If the connected UPS does not use this + variable, it is set to ‘NOT SUPPORTED’. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: @@ -7006,8 +7006,8 @@ the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to determine the values of the flags, this variable is set - to ‘UNKNOWN’. If the connected UPS does not use this - variable, it is set to ‘NOT SUPPORTED’. + to ‘UNKNOWN’. If the connected UPS does not use this + variable, it is set to ‘NOT SUPPORTED’. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: @@ -22524,7 +22524,7 @@ DESCRIPTION "An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of - the ARU is unknown, this variable is set to ‘UNKNOWN’. + the ARU is unknown, this variable is set to ‘UNKNOWN’. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: