Dialog Configure Axis REFRESH . CONFIRM Min Max Expt Start Stop Clear Traces Save Data Started User Stopped Cleared Traces and Data No data to save Traces saved to Error. Try Device->Reconnect Voltage (V) Current (mA) FIT with I=Io* exp(qV/nkT) Fitted with Diode Equation : Io = mA , Ideality factor = Analysis failed. Could not fit data Completed plotting I-V SQ1 Frequency can be changed from 1 Hz to 50Hz Set SQ1 sqr1 set to Hz Trials Time Period (mSec) Pendulum length cm Clear Data and Traces Number of trials Frequency of Oscillation = Hz. Damping Factor = Timeout Completed Invalid Number of trials Invalid Length Started Measurements Voltage messages Frequency (Hz) From From to to Hz Number of Steps = Number of Steps = Invalid Frequency limits Measurement in progress Time (mS) Select Range of A1 4 V Start Scanning Noise = V. Drop the Magnet until a trace is captured Induced voltage Detected voltage above threshold. Peak voltages: Voltage(V) Total Duration Seconds Measure every Data logger plot completed Invalid Duration Invalid time interval between reads Duration No Traces available for saving Vbase (via 100kOhm) V Base valtage shold be from .5 to 3 Invalid Base valtage, shold be from .5 to 3 Analyze last Trace Set SQ1 Frequency For Driven Pendulum Expt. Set SQ1 Frequency For Driven Pendulum Expt. Time Vs Angular velocity plot completed Current through R (mA) Voltage across R(Volts) R to Ground Ohm Starting PV1 Change Voltage Voltage = %5.3f Current = 0 mA Voltage = %5.3f V Current = %5.3f mA Slope of the Line (dV/dI) = Err Timebase mS/div 0 -> 5V step on OD1 5 -> 0V step on OD1 Calculate RC Clear Data & Traces Resistance = No data to analyze. Fitted data with V=Vo*exp(-t/RC). RC = mSec Failed to fit the curve with V=Vo*exp(-t/RC) Cleared Data and Traces AWG set to WG Impedance Calculator F (in Hz) R (in Ohms) C (in uF) L (in mH) Calculate XL, XC and Fo Curve fitting result rejected Data Analysis Error Vtotal (A1) = %5.2f V Vr (A2) = %5.2f V Vlc (A2-A1) = %5.2f V F = %5.1f Hz Phase Diff = %5.1f deg Invalid Input in some field Rext = Analyse latest Data Clear Data Resonant Frequency = kHz Damping factor= Failed to fit the curve Analyse last Trace Enter a valid Resistance L/R = mSec : Rind = Ohm : L = mH Failed to fit the curve with V=Vo*exp(-t*L/R) Reconnecting... Error. Could not connect. Check cable. Fundamental frequency = %5.1f Hz Frequency Spectrum FFT Error Time: %6.2fmS %s:%6.2fV %5.2f V, %5.1f Hz %5.0f Ohm Range of set to pF nF uF %5.1fHz %4.1f%% No signal SQ1 Change of Freqency effected only after Enable/Disable controls. shows the actual frequency set. Change of Freqency effected only after Enable/Disable controls. shows the actual frequency set. Enable WG Enable SQ1 Enable Measurements FFT err Disable before Saving Trace saved to Amplitude (V) in in seconds seconds Frequency = %5.0f Hz V = %5.3f Completed in Seconds Invalid Time interval Increase time interval to or Reduce frequency span mS at each step Phase Shift = Measure start.. Time of flight = Error. Try again Ending PV1 Starting Ending Total time Sec Calibrated Not Calibrated Device Reconnected: %s %5.3f V Res on SEN: out of range sqr2 set to Form Form A2 A2-A1 . Measure Voltages <html><head/><body><p><span style=" font-weight:600;">Amplitude</span> and <span style=" font-weight:600;">frequency</span> extracted from the</p><p>sinusoidal signal using least square fitting.</p><p><br/></p><p>This assumes a sine wave input is provided.</p><p><br/></p><p>For mixed signals, use the FOURIER transform button</p><p>below.</p></body></html> Volts symmetric Hz symmetric volts SQ1 Current Source Voltage: Current Source Voltage: Timebase Trigger SAVE Traces CCS Fourier Transform Resistance on SEN Frequency (IN2): OD1 Capacitance (IN1): A1 FREEZE Cursor IN2 IN1 SQ2 PVS MainWindow Voltage measurement Resistance measurement Resistors in Series Resistors in Parallel Capacitance measurement Capacitors in Series Capacitors in Parallel Resistance by Ohm's law Direct and Alternating Currents AC mains pickup Separating AC and DC Conducting Human body Resistance of Human body Light Dependent Resistor Lemon Cell Simple AC generator Transformer Resistance of Water Generating Sound Digitizing Sound Stroboscope Oscilloscope அலைக்காட்டி Diode Characteristics NPN Output Characteristics RLC transient response Halfwave Rectifier Fullwave Rectifier Diode Clipping IC555 Multivibrator Logic Gates Plot I-V Curve RLC Steady state response RC Transient response RL Transient response Gravity by Time of Flight Electromagnetic Induction Sound beats Rod Pendulum with Light barrier Pendulum Wavefrorm Driven Pendulum resonance Data Logger Enable PopUp Help Window Failed to load scope Failed to load scope Failed to load %s Failed to load %s No immediate application Please restart the application to lighten the screen's background Please restart the application to darken the screen's background. Device உபகரணங்கள் Reconnect LightBackGround next time DarkBackGround next time Choose Language School Expts Electronics Electrical Sound Mechanics Other Expts Credits editorHandler Failed to load scope Failed to load scope Failed to load %s Failed to load %s helpWin Help: %s